| Digital Generator Protection Relay (Vector Jump Relay) VECFU5 | |
![]() |
• Acc. to german EVU-standards for protective equipments |
Download specifications (.PDF) VECFU5 / 3/4-conductor 231V/400V 45 – 70Hz, Cl. 0.5 VECFU5 with R.O.C.O.F. |
|
This unit protects the generator when phase jumps occur in mains-parallel operation and constantly monitors the 3-phase mains voltage applied and the mains frequency in mains-parallel operation. The output contacts for phase jump, undervoltage and underfrequency are switched as working contacts which automatically switch off the system when undervoltage or underfrequency errors occur. As the rapid switch-off provided by the phase monitoring function causes the unit to immediately disconnect from the mains, there is no short-circuit switch-off (with subsequent total failure), so the system can be automatically reconnected to the mains after a certain mains settling time. |
|
| Mains / Generator Protecting Relay VECFU1 (discontinued) | |
![]() |
• Rapid phase jump triggering within 10 - 50ms |
Download data sheets (.PDF) VECFU1 4-conductor N 231V 50Hz +/-20% |
|
This unit protects the generator when there are phase jumps in parallel operation and constantly monitors the 2-phase mains voltage applied and the mains frequency.The output contacts are switched as normally open contacts so that the system swiches off automatically when faults occur. As a result of the rapid switch-off, short circuit switch off ( with subsequent total failure ) does not yet take place, so the system can be automatically connected to the mains again after a mains stabilization time. |
|
| Mains / Generator Protection Relay VEC100 (discontinued) | |
![]() |
• Rapid phase jump triggering within 10 - 50ms Note: |
Download data sheets (.PDF) VEC100 2-conductor 231V 50Hz |
|
The unit protects the generator when there are phase jumps in parallel mains operation. The output pads are switched as normally open contacts so that the system switches off automatically, even at mains faillure. When the preset phase jump value is exceeded, the output contact opens within 10 - 50ms. As a result of the rapid switch-off, short circuit switch off ( with subsequent total faillure ) does not yet take place, so the system can be automatically connected to the mains again after a mains stabilization time. |
|
| Reverse Power Time Relay RLZ110, RLZ113, RLZ150, RLZ153 | |
![]() |
• Real reverse power measurement throught four-quadrant detection |
Download data sheets (.PDF) RLZ110 4-conductor symm. 231V, 1A (IR) RLZ150 4-conductor symm. 231V, 5A (IR) RLZ113 3-conductor symm. 231V, 1A (IR) RLZ153 3-conductor symm. 231V, 5A (IR) |
|
The reverse power relay RLZ ( one-phase ) protects the generator from reverse power from the mains. The effective power is detected via a high-precision four- quadrant multiplier which evaluates the effective power regardless of the curve form of the mains voltage. When the reverse power set is exceeded and the timing circuit is completed, the output relay switches through. The switching states are displayed via LED. |
|
| Independent Overcurrent / Short-circuit Time Relay IOS310, IOS31G, IOS350, IOS35G | |
![]() |
• 3-phase AC current monitoring |
Download data sheets (.PDF) IOS31G 1A (IR), 1,5 - 2,7A (IS) IOS310 1A (IR), 2,0 - 10A (IS) IOS35G 5A (IR), 7,5 - 13,5A (IS) IOS350 5A (IR), 10 - 50A (IS) |
|
3-phase protective device for time-selective overcurrent and short-circuit switch-off in generator and switchgear systems.The unit has an independent power supply and contains 2 seperate trigger circuits with adjustable trigger currents and trigger times. All 3 phases are evaluated individually and the highest value in each phase causes triggering after the value set is exceeded. In the outputs, the switching information is passed on via high-precision two-way contacts ( 250V, 5A ). |
|
| Independent Short-circuit Time Relay I-S310, I-S31G, I-S350, I-S35G, I-S354 | |
![]() |
• 3-phase AC current monitoring |
Download data sheets (.PDF) I-S310 1A (IS), 2,0 - 10A I-S31G 5A (IS), 10 - 50A |
|
3-phase protective device for time-selective short-circuit switch-off in generator and switchgear systems. The unit has an independent power supply and contains 1 trigger circuit with adjustable trigger currents and trigger times. All 3 phases are evaluated individually and the highest value in each phase causes triggering after the value set is exceeded. In the outputs, the switching information is passed on via high-pecision two-way contacts ( 250V, 5A ). |
|